Leading Exporters, Wholesaler, Distributor of Aquasol AE402 Amine Test Kit, Aquasol AE411 Phosphonate Test Kit, Aquasol AE412 Amine Test Kit, Aquasol AE501 Total Hardness Testing Kit, Aquasol AE511 Total Hardness Testing Kit, Aquasol AE521 Total Hardness Testing Kit, Aquasol AE531 Total Hardness Testing Kit, Aquasol AE541 Total Hardness Testing Kit, Aquasol AEOZ3 Ozone Test Kit, Aquasol AEOZ3H Ozone Test Kit, Aquasol Arsenic Test Kit, Aquasol Bromine Test Kit, Aquasol Carbon Dioxide Test Kit, Aquasol Chemical Oxygen Demand Test Kit, Aquasol Chlorine Dioxide Test Kit, Aquasol Chromate Hexavalent Test Kit, Aquasol Copper Test Kit, Aquasol Dissolved Oxygen Test Kit, Aquasol Fluoride Test Kit, Aquasol Hydrazine Test Kit, Aquasol Hydrogen Peroxide Test Kit and Aquasol Iodine Test Kit from Thane.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 5-100 & 50-1000 mg/l as Cyclohexylamine |
No of Test | 300 |
Application | For Boiler Water Only |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AE402 |
Preferred Buyer From
Location | Worldwide |
Amines are used as neutralizing agents for condensation water in boiler treatment. This helps to control corrosion.Our Aquasol AE402 alkalinity kit is very easy to use test to gives reliable results in terms of cyclohexamine.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 2-40 & 5-100 mg/l as HEDP |
No of Test | 300 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AE411 |
Preferred Buyer From
Location | Worldwide |
Phosphonates a are a class of chelating agents and scale inhibitors used in household cleaning products personal care products institutional cleaners and industrial cleaning processes and water treatment additives in various applications. They play an important role in boiler cooling and process water treatment. Our AE411 phosphonate water testing kit is available for low range is used by boiler maintenance personnel frequently.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 1-20 mg/l as Cyclohexylamine |
No of Test | 300 |
Application | For Boiler water only |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AE412 |
Preferred Buyer From
Location | Worldwide |
Amines are used as neutralizing agents for condensation water in boiler treatment. This helps to control corrosion.Our Aquasol AE412 alkalinity kit is very easy to use test to gives reliable results in terms of cyclohexamine.
Business Type | Exporter, Supplier, Distributor |
Product Range | 2-40 & 5-100 mg/l as CaCO5 |
No of Test | 500 |
Brand Name | Aquasol |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AE501 |
Preferred Buyer From
Location | Worldwide |
WWhen water passes through or over deposits such as limestone the levels of ca2+ mg2+ and hco3 ions present in the water greatly increase and cause the water to be classified as hard water. Hardness in water is caused by dissolved minerals and calcium and magnesium ions are usually present in significant concentration along with other divalent ions. Hardness creates scale deposit problem which lead to energy loss in different industrial systems such as boiler cooling system cause scale formation in plumbing heating appliances and boilers. Measuring total hardness is essential to monitor – softener demineralization RO plant softening processes etc. Our AQUASOL AE501 hardness range is one of the largest available in the market today. It is a premium kit and finds use in almost all industries where water is the most important ingredient/parameter.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 2-40 & 25-500 mg/l as CaCO5 |
No of Test | 500 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AE511 |
Preferred Buyer From
Location | Worldwide |
When water passes through or over deposits such as limestone the levels of ca2+ mg2+ and hco3 ions present in the water greatly increase and cause the water to be classified as hard water. Hardness in water is caused by dissolved minerals and calcium and magnesium ions are usually present in significant concentration along with other divalent ions. Hardness creates scale deposit problem which lead to energy loss in different industrial systems such as boiler cooling system cause scale formation in plumbing heating appliances and boilers. Measuring total hardness is essential to monitor – softener demineralization RO plant softening processes etc. Our AQUASOL AE511 hardness range is one of the largest available in the market today. It is a premium kit and finds use in almost all industries where water is the most important ingredient/parameter.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 5-100 & 25-500 mg/l as CaCO3 |
No of Test | 500 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AE521 |
Preferred Buyer From
Location | Worldwide |
When water passes through or over deposits such as limestone the levels of ca2+ mg2+ and hco3 ions present in the water greatly increase and cause the water to be classified as hard water. Hardness in water is caused by dissolved minerals and calcium and magnesium ions are usually present in significant concentration along with other divalent ions. Hardness creates scale deposit problem which lead to energy loss in different industrial systems such as boiler cooling system cause scale formation in plumbing heating appliances and boilers. Measuring total hardness is essential to monitor – softener demineralization RO plant softening processes etc. Our AQUASOL AE521 hardness range is one of the largest available in the market today. It is a premium kit and finds use in almost all industries where water is the most important ingredient/parameter.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 1-20 & 5-100 mg/l as CaCO3 (500 Tests) |
No of Test | 500 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AE531 |
Preferred Buyer From
Location | Worldwide |
When water passes through or over deposits such as limestone the levels of ca2+ mg2+ and hco3 ions present in the water greatly increase and cause the water to be classified as hard water. Hardness in water is caused by dissolved minerals and calcium and magnesium ions are usually present in significant concentration along with other divalent ions. Hardness creates scale deposit problem which lead to energy loss in different industrial systems such as boiler cooling system cause scale formation in plumbing heating appliances and boilers. Measuring total hardness is essential to monitor – softener demineralization RO plant softening processes etc. Our AQUASOL AE531 hardness range is one of the largest available in the market today. It is a premium kit and finds use in almost all industries where water is the most important ingredient/parameter.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 50 -1000 mg/l as CaCo3 |
No of Test | 500 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AE541 |
Preferred Buyer From
Location | Worldwide |
When water passes through or over deposits such as limestone the levels of ca2+ mg2+ and hco3 ions present in the water greatly increase and cause the water to be classified as hard water. Hardness in water is caused by dissolved minerals and calcium and magnesium ions are usually present in significant concentration along with other divalent ions. Hardness creates scale deposit problem which lead to energy loss in different industrial systems such as boiler cooling system cause scale formation in plumbing heating appliances and boilers. Measuring total hardness is essential to monitor – softener demineralization RO plant softening processes etc. Our AQUASOL AE541 hardness range is one of the largest available in the market today. It is a premium kit and finds use in almost all industries where water is the most important ingredient/parameter.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 0.05 – 1.00 PPM |
No of Test | 100 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AEOZ3 |
Preferred Buyer From
Location | Worldwide |
Ozone is a strong oxidizing agent and is used as a biocide in the disinfection of water. It is also used in various sterilization processes in the food and beverage and pharmaceutical industries. Ozone is very effective in removing bad odours and flavours because it breaks down into oxygen which improves taste and other qualities of water. The amount of Ozone required in a water system is determined by Ozone demand and contact time of the water. Our AQUASOL AEOZ3 ozone test is available as DPD method and the kit gives very reliable results. The end point is very sharp and easily discernable by the user and even a shop floor worker will be able to get desired results with our test kit.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 0.25 – 5.00 PPM as 03 |
No of Test | 100 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AEOZ3H |
Preferred Buyer From
Location | Worldwide |
Ozone is a strong oxidizing agent and is used as a biocide in the disinfection of water. It is also used in various sterilization processes in the food and beverage and pharmaceutical industries. Ozone is very effective in removing bad odours and flavours because it breaks down into oxygen which improves taste and other qualities of water. The amount of Ozone required in a water system is determined by Ozone demand and contact time of the water. Our AQUASOL AEOZ3H ozone test is available as DPD method and the kit gives very reliable results. The end point is very sharp and easily discernable by the user and even a shop floor worker will be able to get desired results with our test kit.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 0.0 to 3.0 mg/l as Arsenic |
No of Test | 100 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AE408 |
Preferred Buyer From
Location | Worldwide |
Arsenic in drinking-water is a hazard to human health. The main source of arsenic in drinking-water is arsenic-rich rocks through which the water has filtered. It may also occur because of mining or industrial activity in some areas. AQUASOL AE408 arsenic test kit provides easy-to-use low-cost method for measuring arsenic levels in water.This water test kit is quite novel and one its kind. It is the effort of our in house Research and developement.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 0.1 to 2.0 mg/I as Bromine |
No of Test | 100 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AE404 |
Preferred Buyer From
Location | Worldwide |
Bromine substances are disinfectants and can be used as an alternative for chlorine. In swimming pools, bromine is used against the formation and growth of algae, bacteria and odors in swimming water.Our AQUASOL AE404 bromine test is based on dpd method and results obtained are easily discernable.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 2-40 & 10-200 mg/l as CO2 |
No of Test | 300 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AE403 |
Preferred Buyer From
Location | Worldwide |
Carbon dioxide can react with water to form carbonic acid (h2co3). Carbonic acid will cause corrosion in steam and return lines. Carbon dioxide can originate from condenser air leakage or bicarbonate (hco3) alkalinity in the feed water.Our AQUASOL AE403 test for carbon dioxide is a titrimetric kit packaged with standardized reagents ready to use convenient and accurate.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 40 to 400 mg/l as COD |
No of Test | 100 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AE407 |
Preferred Buyer From
Location | Worldwide |
Chemical Oxygen Demand (COD) is defined as the amount of a specific oxidant that reacts with the sample under controlled conditions. The quantities of oxidant consumed is expressed in terms of its oxygen equivalence.
Because of Dichromate ions specific oxidant properties (CrO72-) unique chemical properties it gets reduced to the chromic ion (Cr3+) in COD test.
COD is a defined test the extent of sample oxidation can be affected by digestion time reagent strength and sample COD concentration.
COD is often used on a measurement of pollutants in waste water and natural water.
To determine COD two methods are useful the open reflux method is suitable for a wide range of waste water and large sample size is preferred. Another is the closed reflux method is suitable for smaller quantities. It requires homogenisation of sample. Accurate measurement of sample values as well as reagent volumes and concentration are critical.
Principle
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 0.2-4.0 mg/l as Chlorine Dioxide |
No of Test | 100 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AE405 |
Preferred Buyer From
Location | Worldwide |
Chlorine dioxide is a broad-spectrum micro biocide effective over a wide ph range. Chlorine dioxide is effectively used in the control of microbiological growths in industrial cooling waters under conditions unfavorable to chlorine. Our AE405 water test is a titrimetric one generally used by cooling tower maintenance personnel to monitor residuals of the oxidising microbiocide.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 5-100 & 25-500 mg/l as Chromate |
No of Test | 200 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AE208 |
Preferred Buyer From
Location | Worldwide |
Chromate is produced in pickling and plating operations anodizing aluminium leather tanning manufacturing of paints dyes and explosives. Chromate is used to inhibit corrosion in open and closed system cooling towers. This AQUASOL AE208 water test kit is generally used by paint and dye manufacturers and very rarely for monitoring cooling systems as with the advent of technology newer safer biocides are being used and chromate has almost left the scene.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 0.025 to 5.0 mg/l as Copper |
No of Test | 250 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AE310 |
Preferred Buyer From
Location | Worldwide |
Copper is a metal that exists in the environment as a mineral in rocks and soil. It is commonly found at low levels in natural water bodies. Consumption of high levels of copper can cause nausea vomiting diarrhoea gastric complaints and headaches. Copper salts are used to control algae. The copper water test kit is based on colour comparison and can do 250 tests.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 0.5 – 8.0 mg/l as Oxygen |
No of Test | 250 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AEDO8 |
Preferred Buyer From
Location | Worldwide |
D.O. is essential for the aquatic plant and animal life. DO is detrimental in boiler systems because it leads to corrosion in boiler systems. DO analysis measures the amount of gaseous oxygen (o2) dissolved in an aqueous solution DO measurement is a tricky business, but our Aquasol AED08 kit makes testing easy and simple.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 0.1-2.0 & 1-20 mg/l as Fluoride |
No of Test | 500 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AE210 |
Preferred Buyer From
Location | Worldwide |
Fluoride occurs naturally in all types of water. Typically surface waters and sea waters have low concentration of fluoride while groundwater may contain high levels of fluoride as it may be exposed to many inorganic fluoride-containing minerals. Fluoride salts are also frequently encountered in many industrial applications. Fluoride is important in drinking water as excessive fluoride cause mottling. A permissible limit has been laid down for fluoride therefore analysis of fluoride is mandatory in drinking water. Our AE210 fluoride water test is one of its kinds and works on the titrimetric principle. The end point is a clear yellow.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 0.1 to 1.25 mg/l as Hydrazine |
No of Test | 200 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AE304 |
Preferred Buyer From
Location | Worldwide |
Hydrazine is used as an oxygen scavenger for high pressure boilers in power plants and other industries to reduce corrosion of metal pipes and fittings. Our AE304 hydrazine water test kit is regular used for high pressure boiler monitoring the results are easily discernable and can be used by shop floor personnel.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 5-100 & 50-1000 mg/l as H2O2 |
No of Test | 300 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AEHP |
Preferred Buyer From
Location | Worldwide |
The corrosiveness of process water due to hydrogen peroxide depends on the amount of dissolved oxygen that is produced. Oxygen corrodes iron-containing metals. Hydrogen peroxide is used as a disinfectant. H2o2 is used to disinfect drinking water. It is also used to combat excessive microbial growth in water systems and cooling towers. AQUASOL hydrogen peroxide test kit helps to estimate the concentration of h2o2 in water.
Business Type | Exporter, Supplier, Distributor |
Brand Name | Aquasol |
Product Range | 0.1 -2.0 ppm |
No of Test | 100 |
Manufacturer | Rakiro Biotech Systems Private Limited |
Product Code | AE406 |
Preferred Buyer From
Location | Worldwide |
Iodine is present in natural sea water and this iodine occurs as several different species including iodide, iodate, molecular iodine and hypoiodite. Test kits which are not capable of detecting iodate are not suitable for aquarium use, since in a properly functioning tank most of the iodide will be transferred to iodate and any test kits not able to detect iodate will give a false, low iodine reading. Iodine test kits should be capable of measuring all forms of naturally occurring iodine. Our Aquasol AE406 Iodine is the only one offering this feature, measuring all naturally occurring iodine compounds and giving a reading of total iodine concentration.